Engineered Process Controls, LLC

COMPANY

OVERVIEW

EXPERIENCE

EMPLOYMENT

CONTACT & DOWNLOADS

QUOTE REQUEST

PLACE AN ORDER

DOWNLOADS

ORDER INFO/UPDATE

SUPPORT / CONTACT

PRODUCTS

ANALYZERS & GAS DETECTION

BOILER FLAME SCANNERS

CONTROL VALVES

FLOW TECHNOLOGIES

EX. PROOF PHONES/TABLETS

LEVEL TECHNOLOGIES

PNEUMATIC CONTROLS

POWER & STEAM PRODUCTS

PRESSURE & TEMPERATURE

REGULATORS

SNOW MELTING/HEAT TRACING

VALVES & CONTROLS

VIBRATION CONTROLS

WIRELESS NETWORKS

SUPPLIERS

3Z VALVES

ACCUSEAL

ACCUTECH - FOXBORO

ADAMS VALVES

BRONKHORST

DELTATHERM

DREXELBROOK

EBRO & STAFSJO VALVES

ECOM

ELPRO TECHNOLOGIES

FOXBORO

FOSSIL POWER

HONEYWELL ANALYTICS

HONEYWELL IFM

KA TRONICS TECHNOLOGIES

K-PATENTS

MAGNETROL

LUMA SENSE

ORION INSTRUMENTS

OSI

PEPPERL FUCHS

ROBERTSHAW

ROTORK CONTROLS

STAFSJO

TELEDYNE

TYPE K

VIBROMETER / OMNIGUARD

WALTRON

Helpful Links

Engineering Calculator

Providing Process Measurement & Controls Solutions

Drexelbrook

AMETEK Drexelbrook is known throughout the world as a leader in level measurement technology. They have earned their reputation for excellence from over five decades of experience in providing level solutions to virtually every industry including oil and gas, chemical, petrochemical, refining, power, water and wastewater, food, pharmaceutical, pulp and paper, mining, automotive, and many others.




Point Level Measurment:

RF Admittance Level Measurement:

Z-Tron IV Level Switch
Key Features:
  • DPDT relay closure
  • Power requirements
  • AC Units (field adjustable): 95-145 VAC, 50/60 Hz, 2 Watt
  • DC Units: 24 VDC Unit: 19-29 VDC input, 2 Watt
  • Operating point range: 0-80 pF (20 turn pot / 4 pF per turn). Extended range with external pad capacitator, pad ratio 1:1

ThePoint - Line Powered Level Switch
Key Features:
  • Cote-Shield circuitry ignores coatings
  • No moving parts for maintenance free operation
  • Applications from cryogenic to 500ºF, vacuum to 1,000 psi
  • Supply voltage: 19-250 VAC, 18-200 VDC, Auto-detecting without jumpers

ThePoint - Loop Powered Level Switch
Key Features:
  • Reliable overfill protection
  • Cote-Shield circuitry ignores coatings
  • No moving parts for maintenance free operation
  • Applications from cryogenic to 500ºF, vacuum to 1,000 psi
  • Supply voltage: 13-30 VDC
  • Output: 8mA (alarm), 16mA (normal) or 8mA (normal), 16mA (alarm)

IntelliPoint RF - Line Powered Level Switch
Key Features:
  • AutoVerify and Certify test features for critical point level and overfill protection applications
  • Cote-Shield circuitry ignores coatings on the level sensing probe
  • No moving parts for maintenance free operation
  • Level applications from cryogenic to 2,000ºF, vacuum to 10,000 psi
  • Supply voltage: 85-250 VAC, 21-100 VDC auto-detecting without jumpers, DC to 400 Hz

Safety IntelliPoint - Loop and Line Powered Level Switch
Key Features:
  • Loop and Line powered SIL 2 certified
  • AutoVerify and Certify test features for critical point level and overfill protection applications
  • Cote-Shield circuitry ignores coatings on the level sensing probe
  • No moving parts for maintenance free operation
  • Level applications from cryogenic to 2,000ºF, vacuum to 10,000 psi

Safety IntelliPoint - Loop and Line Powered Level Switch
Key Features:
  • Loop and Line powered SIL 2 certified
  • AutoVerify and Certify test features for critical point level and overfill protection applications
  • Cote-Shield circuitry ignores coatings on the level sensing probe
  • No moving parts for maintenance free operation
  • Level applications from cryogenic to 2,000ºF, vacuum to 10,000 psi

Floating Roof Tanks Spill Prevention
Key Features:
  • Loop or Line Powered
  • Wetted Parts: 316SS 3/4" NPT Mounting, 3/16" FEP insulated flexible and adjustable cable, non-sparking brass sensor.
  • Automatic and local or remote maual test functions ensure proper system operation.
  • One system fits most floating roof tank applications, reducing field spanes
  • Adjustable insertion lengths up to 15' (4,6m)
  • Excellent trip point accuracy over a wide range of medias and tank roof

ClearLine Level Switch
Key Features:
  • Ambient temperature: -40 to 140°F (-40 to 60°C)
  • Time delay: Adjustable 0-120 sec for pump start/stop
  • Process temperature and pressure: 250°F at 100 PSI (121°C at 7 bar)

Dumpstar Level Switch
Key Features:
  • Ambient temperature effect: <0.1-inch/100°F
  • Ambient operating temperature: -40°F to 140°F
  • Process temperature: 0-300°F
  • Process temperature and pressure: 300°F at 150 PSI
  • Sensitivity: .01-inch standard
  • Time delay: 0-90 seconds, standard

MultiPoint II Level Switch
Key Features:
  • Operating Point Range: 0-200 ft (depending on sensing elements)
  • Supply voltage: 95-145 VAC 50/60 Hz 1 watt or 205-255 VAC 50/60 Hz 1 watt
  • Operating temperature: -40°F to 140°F  (-40°C to 60°C)
  • Three DPDT relays: One one with 0-90 second adjustable time delay, one on/off, one with adjustable differential*

Plugged Chute Detector
Key Features:
  • Curved and flat sensors are available
  • DPDT relay dry contacts at 5A, 120VAC
  • Less maintenance than other technologies; no moving parts to hang up or wear out
  • Uses Drexelbrook PML series electronics
  • Supply voltage: 19-250 VAC, 18-200 VDC, Auto-detecting without jumpers

Vibration Level Measurement:

TF 100 Series Vibrating Level Switch
Key Features:
  • Relay, current, or PNP outputs
  • Temperatures from -58ºF to 302ºF, Pressure from vacuum to 928 psi
  • No calibration required

Ultrasonic Level Measurement:

VeriGAP Ultrasonic Level Sensor
Key Features:
  • AutoVerify and Certify test features
  • No moving parts for maintenance free operation
  • Applications to 350ºF at 1,000 psi
  • DPDT relay output

USonic Ultrasonic Level Transmitter
Key Features:
  • Patented SMART GAIN circuitry automatically ignores false echoes from internal tank obstructions and agitator blades without adjustment
  • Superior accuracy – 0.15% of measuring range up to 30 ft
  • Two wire HART intrinsically safe or explosion proof, suitable for Class 1, Division 1, hazardous locations
  • Output mode: Level, Distance, Flow, Volume
  • Power supply: 19 to 30 VDC. 19 VDC required at 4 mA minimum

USonic-R Ultrasonic Level Transmitter
Key Features:
  • Patented SMART GAIN circuitry automatically ignores false echoes from internal tank obstructions and agitator blades without adjustment
  • Superior accuracy – 0.15% of measuring range up to 30 ft
  • Line powered design offers 6 programmable relays, 2 channel input for differential level, batch sample activation, pump alternation, data logging, and totalization
  • Output mode: Level, Distance, Flow, Volume
  • Power supply: 120 VAC and 24 VDC, 240 VAC and 24 VDC

Continous Level Measurment

RF Admittance Level Measurement:

Universal II Level System
Key Features:
  • No calibration shifts due to changes in temperature or material densities
  • Can be remotely mounted up to 100 feet from the sensing element
  • Available as intrinsically safe systems
  • Output: 4-20 mAdc
  • Supply voltage: 11.5-50 VDC at transmitter

Universal IV Level System
Key Features:
  • Easy one-time calibration
  • Low cost of ownership, no maintenance and no moving parts to wear out
  • Immuine to tank obstructions such as nozzles, ladders, pipes and agitators
  • Available as intrinsically safe systems
  • Output: 4-20 mAdc, HART. Compatible with HART.
  • Supply voltage: 13-30 VDC, 2 wire loop powered

Desalter Interface Level Transmitter
Key Features:
  • Maximize throughput by reducing water content in crude oil
  • Measures close to the grids
  • Measurement independent of density, temperature, and pressure changes
  • Explosion-proof and intrinsically safety approvals
  • Output: 4-20 mA, Current Limit to 28 mA
  • Supply voltage: 24 VDC Nominal (works with 11.5 to 50 VDC)

Hydrostatic Pressure Level Measurement:

Level Mate III Level Measurement System
Key Features:
  • Complete level system – all in one package
  • Low system pricing
  • Wide range of reliable stainless steel sensors
  • Setpoints and signal outputs for remote monitoring, recording and control
  • Meter temperature range: -40° to 65° C (-40° to 150°F)
  • Meter power requirements: 85 to 265 VAC @ 50/60 Hz, 90-265 VDC, 20 W max
  • Transmitter temperature range: -40° to 82°C (-40° to 180°F)
  • Transmitter power requirements: 24 VDC from meter

Model 375 Submersible Level Transmitter
Key Features:
  • Low cost
  • Easy to install and use
  • Reverse polarity and surge protected
  • Pressure range: 0-6 psi to 0-300 psi
  • Operating temperature:
  • Pressure Ranges up to 150 PSI  -25 to 60°C (-13 to 140°F)
  • Pressure Ranges Above 150 PSI -25 to 25°C (-13 to 77°F)


Model 575P Submersible Level Transmitter
Key Features:
  • Easy to install and use
  • Popular measurement ranges up to 690 Ft.
  • Rugged 316SS body with excellent environmental protection
  • Flush mounted diaphragm is protected by a stainless steel plate that prevents sensor fouling
  • Temperature Range: -25ºF to 180ºF (-32ºC to 82ºC)
  • Power supply: 12 to 40 VDC with reverse polarity surge protection

Model 575S Submersible Level Transmitter
Key Features:
  • Easy to install
  • Popular measurement ranges up to 690 Ft.
  • Power supply: 12 to 40 Vdc with reverse polarity surge protection
  • Temperature range: CSA intrinsically safe T3C = 32°F to 140°F (0°C to 60°C)

Model 675 Submersible Level Transmitter
Key Features:
  • Intrinsically Safe for Class 1 Division 1 
  • Custom Pressure Ranges & Cable Lengths 
  • Extremely rugged 316L SS construction  
  • Temperature range: -25° to 180°F (-32° to 82°C)
  • Power supply: 12 to 40 VDC with reverse polarity surge protection

Model SDT Submersible Level Transmitter
Key Features:
  • Compact size
  • Vented to atmosphere through surface end of cable
  • Reverse polarity and surge protected
  • Power supply: 11-30 VDC
  • Temperature range: -25°C to 60°C (-13°F to 140°F)

Model SST Slimline Submersible Level Transmitter
Key Features:
  • Removable snub nosed end protects sensing diaphragm
  • Temperature range: -13º to 167º F (-15º to 75º C)
  • Power supply: 11 to 30 VDC with Reverse Polarity Surge Protection

Copyright 2019 Engineered Process Controls, LLC